High Frequency Online Double Conversion 1kva 2kva 3kva 5kva 6ka 8kva 10kva Ups Data Center Uninterruptible Power Supply
SPECIFICATIONS
High-concerned Chemical: None
Brand Name: Bokpower
Model Number: BKS-1KVA
Phase: Single Phase
Protection: Overvoltage
Weight: Other
Type: On-line
Application: Home Appliance
Electric Energy: 5 Wh
Product name: UPS
Rated power: 1KVA
Input voltage: 220V
Output Voltage: 220V
Battery Type: Lead-acid Maintenance-free Battery
Wave Form: Pure Sine Wave
Power Factor: 1.0
Frequency: 50HZ/60HZ
Brand: Bokpower
Warrenty: 1 Year Warrenty
Warranty: 3months-1year
Description
High Frequency Online double conversion 1kva 2kva 3kva 5kva 6ka 8kva 10kva ups Data Center uninterruptible power supply
Online double conversion UPS, the HS series has a capacity of 1kVA to 10kVA (single-phase input, single-phase output), and the HTS series has a capacity of 1kVA to 10kVA (single-phase input, single-phase output).
1. The power factor of online UPS can reach 0.8 to 1. The overall efficiency reaches 90%.
2. Online UPS has the characteristics of small size, light weight, high efficiency, zero conversion time, pure sine wave output, etc.
3. Wide power input range (110V~300V) high-efficiency frequency conversion mode compatible with generators
4. Adopt the most advanced interface information operation technology, optional exquisite SNMP card, which can be used alone or together with USB and RS232 to achieve perfect monitoring, simple operation and control through the display screen, microprocessor control ensures reliability .
5. Suitable for data processing centers, host systems, comprehensive computer networks, ISP services, telecommunications, computer rooms, etc.
6. Realize online double conversion
7. Does not support parallel function
Specifications:
MODEL |
1K |
2K |
3K |
|
CAPACITY* |
1000 VA / 800 W |
2000 VA / 1600 W |
3000 VA / 2400 W |
|
INPUT |
||||
Voltage Range |
Low Line Transfer |
160VAC/140VAC/120VAC/110VAC± 5% (Ambient Temp.<350C) ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) |
||
Low Line Comeback |
175VAC/155VAC/135VAC/125VAC ± 5 % (Ambient Temp.<350C) ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) |
|||
High Line Transfer |
300 VAC ± 5 % |
|||
High Line Comeback |
290 VAC ± 5 % |
|||
Frequency Range |
40Hz ~ 70 Hz |
|||
Phase |
Single phase with ground |
|||
Power Factor |
≥ 0.99 @ nominal voltage (input voltage) |
|||
OUTPUT |
||||
Output voltage |
200/208/220/230/240VAC |
|||
AC Voltage Regulation |
± 1% (Batt. Mode) |
|||
Frequency Range |
47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range) |
|||
Frequency Range (Batt. Mode) |
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz |
|||
Overload |
Ambient Temp.<350C 105%~110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass when the utility is normal 110%~130%: UPS shuts down after 1minute at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal |
|||
Current Crest Ratio |
3:1 |
|||
Harmonic Distortion |
≤ 3 % THD (linear load); ≤ 6 % THD (non-linear load) |
|||
Transfer Time |
AC Mode to Batt. Mode |
Zero |
||
Inverter to Bypass |
4 ms (Typical) |
|||
Waveform (Batt. Mode) |
Pure Sinewave |
Product Images