SPECIFICATIONS
Application: Solar Power System Home
Brand Name: Solis
Cooling Method: Intelligent redundant fan-cooling
Efficiency: 97.8%
High-concerned chemical: None
Input Voltage: 100V-550V
Inverter Efficiency: 96.02%
Model Number: S6-EH2P16K03-NV-YD-L-US
Monitoring: CAN, RS485, Ethernet,
Operating temperature range: -25°C ~ 60°C
Output Current: 72.7A
Output Frequency: 50/60HZ
Output Type: DUAL Camera
Output Voltage: Greensun
Product name: solar inverter
Protection: IP66
Self-consumption (night): <25 W
Size: 500*955*297mm
Surge protection: DC Type II / AC Type II
Topology: Transformerless Solar Inverter
Type: Hand Tool Parts,DC/AC Inverters
Weight: 643KG
Products Description
Solis S6-EH2P(10-16)K03-NV-YD-L-US 16KW Hybrid Solar Inverter 51.2V 280ah 314ah Lifepo4 Battery Intelligent redundant fan-cooling



Specifications
|
Model |
S6-EH2P10K03-NV-YD-L-US |
S6-EH2P12K03-NV-YD-L-US |
S6-EH2P14K03-NV-YD-L-US |
S6-EH2P16K03-NV-YD-L-US |
||||
|
Input DC (PV side) |
|
|
|
|
||||
|
Max input voltage |
550V |
|
|
|
||||
|
Normal Voltage |
380V |
|
|
|
||||
|
Starting voltage |
100V |
|
|
|
||||
|
MPPT voltage range |
100V-450V |
|
|
|
||||
|
Max input current per MPPT |
40A |
|
|
|
||||
|
Max short-circuit current per MPPT |
50A |
|
|
|
||||
|
Number of MPPTs / Number of strings per MPPT |
3/2 |
|
|
|
||||
|
Battery |
|
|
|
|
||||
|
Battery Type |
Lithium Ion / Lead-Acid |
|
|
|
||||
|
Battery Voltage Range |
40V-60 V |
|
|
|
||||
|
Maximum Charge/Discharge Current |
208 A |
250 A |
290 A |
290 A |
||||
|
Communication |
CAN / RS485 |
|
|
|
||||
|
Number of Batteries per Inverter |
See Battery Compatibility Sheet |
|
|
|
||||
|
AC Output (Mains) |
|
|
|
|
||||
|
Nominal Output Power |
10KW |
12KW |
14KW |
16KW |
||||
|
Maximum Apparent Output Power |
10KVA |
12KVA |
14KVA |
16KVA |
||||
|
Nominal Output Voltage |
220V |
|
|
|
||||
|
Nominal Grid Frequency |
60HZ |
|
|
|
||||
|
Nominal Grid Output Current |
45.5 A |
54.4A |
63.6A |
72.7A |
||||
|
Maximum Output Current |
45.5 A |
54.4A |
63.6A |
72.7A |
||||
|
THDi |
< 3% |
|
|
|
||||
|
AC Input (Mains) |
|
|
|
|
||||
|
Input voltage range |
193.6 - 242 V |
|
|
|
||||
|
Maximum input current |
200 A |
|
|
|
||||
|
Frequency range |
59.5 - 60.5 Hz |
|
|
|
||||
|
AC Output (Backup) |
|
|
|
|
||||
|
Nominal Output Power |
10 kW |
12 kW |
14 kW |
16 kW |
||||
|
Maximum Apparent Output Power |
2 times the rated power, for 10 s |
|
|
|
||||
|
Backup Response Time |
< 4 ms |
|
|
|
||||
|
Phase Power |
L1/L2/N(PE), 120 V / 240 V (Split Phase) |
|
|
|
||||
|
Nominal Output Voltage (L1-L2) |
220 V |
|
|
|
||||
|
AC Output Voltage Range |
193.6 - 242 V |
|
|
|
||||
|
Nominal Frequency |
60 Hz |
|
|
|
||||
|
Frequency Range |
55 - 65 Hz |
|
|
|
||||
|
Nominal Output Current |
45.5 A |
54.5 A |
63.6 A |
72.7 A |
||||
|
Maximum Output Over Current Protection, 10 sec |
91 A |
109 A |
127 A |
145 A |
||||
|
Max. continuous AC pass-through |
200 A |
|
|
|
||||
|
Maximum allowable phase imbalance |
50% |
|
|
|
||||
|
Backup support configurations |
Dedicated and whole-house loads |
|
|
|
||||
|
Power factor |
> 0.99 (0.8 leading to 0.8 lagging) |
|
|
|
||||
|
THDv (@linear load) |
< 3% |
|
|
|
||||
|
Input Generator |
|
|
|
|
||||
|
Maximum input power: |
24 kW |
|
|
|
||||
|
Maximum input current: |
100 A |
|
|
|
||||
|
Nominal input frequency: |
60 Hz |
|
|
|
||||