{"product_id":"cisco-catalyst-3850-9300-power-supply-715w-ac-hot-swappable-plug-in-module-power-supply-module-with-24pin-715w-pwr-c1-715wac-p","title":"Cisco Catalyst 3850 \/ 9300 Power Supply, 715W AC, Hot-swappable, Plug-in module Power Supply Module with 24Pin 715W PWR-C1-715WAC-P","description":"\u003cp\u003eCisco Catalyst 3850 \/ 9300 Power Supply, 715W AC, Hot-swappable, Plug-in module Power Supply Module with 24Pin 715W PWR-C1-715WAC-P\u003c\/p\u003e\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\n\u003cp\u003eThe Cisco PWR-C1-715WAC-P is a highly reliable and efficient power supply designed for networking hardware. Equipped with an output power of 715W, this AC power supply module supports a wide range of Cisco switches and is built to ensure your network remains operational in various power conditions. Its plug-and-play installation and energy-efficient features make it an excellent choice for businesses looking to optimize their network's performance and resilience.\u003c\/p\u003e\n\n\u003ch3\u003eQuick Specs\u003c\/h3\u003e\n\n\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eProduct Name\u003c\/td\u003e\n\t\t\t\u003ctd\u003ePWR-C1-715WAC-P\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eBrand\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCisco\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePower Output\u003c\/td\u003e\n\t\t\t\u003ctd\u003e715W\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\t\t\t\u003ctd\u003eAC 100-240V\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCompatibility\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCisco Catalyst Series Switches\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e● High-efficiency operation with up to 715W of power output.\u003c\/li\u003e\n\t\u003cli\u003e● Support for automatic failover for maximum uptime.\u003c\/li\u003e\n\t\u003cli\u003e● Hot-swappable design allows for easy installation and replacement without network disruption.\u003c\/li\u003e\n\t\u003cli\u003e● Environmentally-friendly with energy-efficient features to reduce power consumption.\u003c\/li\u003e\n\t\u003cli\u003e● Built-in overvoltage, overcurrent, and overtemperature protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eProduct Applications\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e●Data centers requiring robust power supply backups to maintain network uptime during power fluctuations.\u003c\/li\u003e\n\t\u003cli\u003e●Enterprise-level networks looking to enhance energy efficiency and reduce operational costs.\u003c\/li\u003e\n\t\u003cli\u003e●High-density network environments where reliable power supply is critical for handling high volumes of data and network traffic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSupported Options\u003c\/h3\u003e\n\n\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eRack Mount Kit\u003c\/td\u003e\n\t\t\t\u003ctd\u003eACK-I-RACK-MOUNT-1\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCable Guard\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCGUARD-LX\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eAir Filter\u003c\/td\u003e\n\t\t\t\u003ctd\u003eAFILT-7341\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompare to Similar Items\u003c\/h3\u003e\n\n\u003ctable\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eModels\u003c\/td\u003e\n\t\t\t\u003ctd\u003eDifferences\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePWR-C2-1025WAC\u003c\/td\u003e\n\t\t\t\u003ctd\u003eOutput power of 1025W, higher than PWR-C1-715WAC-P\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePWR-C1-350WAC\u003c\/td\u003e\n\t\t\t\u003ctd\u003eOutput power of 350W, lower than PWR-C1-715WAC-P\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePWR-C1-1100WAC\u003c\/td\u003e\n\t\t\t\u003ctd\u003eOutput power of 1100W, significantly higher than PWR-C1-715WAC-P; best for larger networks\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"1\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd colspan=\"2\"\u003e\n\t\t\t\u003ch3\u003ePWR-C1-715WAC-P Specifications\u003c\/h3\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePower supply rated maximum output power\u003c\/td\u003e\n\t\t\t\u003ctd\u003e715W\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eTotal output BTU\u003cbr\u003e\n\t\t\t(note: 1000 BTU\/hr = 293W)\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2440 BTU\/hr, 715W\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eInput-voltage range and frequency\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e100 to 240 VAC,\u003c\/p\u003e\n\n\t\t\t\u003cp\u003e50 to 60 Hz\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eInput current\u003c\/td\u003e\n\t\t\t\u003ctd\u003e10-5A\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOutput ratings\u003c\/td\u003e\n\t\t\t\u003ctd\u003e-56V at 12.8A\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOutput holdup time\u003c\/td\u003e\n\t\t\t\u003ctd\u003e20 ms minimum at 100VAC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePower-supply input receptacles\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003eIEC 320-C16\u003c\/p\u003e\n\n\t\t\t\u003cp\u003e(IEC60320-C16)\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePower Supply Efficiency\u003c\/td\u003e\n\t\t\t\u003ctd\u003ePlatinum Efficiency\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eMTBF\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1,054,881 (ranges from 1.05M to 2.6M depending on temperature, input voltage and vendor)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePower cord rating\u003c\/td\u003e\n\t\t\t\u003ctd\u003e15A\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003ePhysical specifications\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e(H x W x D): 1.58 x 3.25 x 12.20 in\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eWeight: 2.6 lb (1.2 kg)\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003eNormal operating temperature* and altitudes:\u003c\/p\u003e\n\n\t\t\t\u003cp\u003e●  -5°C to +45°C, up to 5000 feet (1500m)\u003c\/p\u003e\n\n\t\t\t\u003cp\u003e●  -5°C to +40°C, up to 10,000 feet (3000m)\u003c\/p\u003e\n\n\t\t\t\u003cp\u003e*Minimum ambient temperature for cold start is 32°F (0°C)\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eShort-term* exceptional conditions:\u003c\/p\u003e\n\n\t\t\t\u003cp\u003e●  -5°C to +50°C, up to 5000 feet (1500m)\u003c\/p\u003e\n\n\t\t\t\u003cp\u003e●  -5°C to +45°C, up to 10,000 feet (3000m)\u003c\/p\u003e\n\n\t\t\t\u003cp\u003e●  -5°C to +45°C, at sea level with single fan failure\u003c\/p\u003e\n\n\t\t\t\u003cp\u003e*Not more than following in one-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\t\t\t\u003ctd\u003e-40° to 158°F (-40° to 70°C)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eRelative humidity operating and nonoperating noncondensing\u003c\/td\u003e\n\t\t\t\u003ctd\u003e5% to 90% noncondensing\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eAltitude\u003c\/td\u003e\n\t\t\t\u003ctd\u003e10,000 ft. (3000 meters), up to 45°C\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eEMI and EMC compliance\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003eFCC Part 15 (CFR 47) Class A\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eICES-003 Class A\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eEN 55032 Class A\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eCISPR 32 Class A\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eAS\/NZS 3548 Class A\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eBSMI Class A\u003cbr\u003e\n\t\t\t(AC input models only)\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eVCCI Class A\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eEN 55024, EN300386,\u003cbr\u003e\n\t\t\tEN 61000-3-2, EN 61000-3-3\u003c\/p\u003e\n\n\t\t\t\u003cp\u003eEN61000-4-2, EN61000-4-3,\u003cbr\u003e\n\t\t\tEN61000-4-4, EN61000-4-5,\u003cbr\u003e\n\t\t\tEN61000-4-6\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eLED indicators\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\n\t\t\t\u003cp\u003e“AC OK”: Input power to the power supply is OK\u003c\/p\u003e\n\n\t\t\t\u003cp\u003e“PS OK”: Output power from the power supply is OK\u003c\/p\u003e\n\t\t\t\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cbr\u003e\n*PWR-C1-715WAC-UP is available as an PSU upgrade option to 715W primary PSU\u003c\/p\u003e\n","brand":"Let's Fibre Technologies","offers":[{"title":"PWR-C1-715WAC-P","offer_id":48132219830426,"sku":"1601419548899-PWR-C1-715WAC-P","price":12758.49,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0427\/1675\/8170\/files\/Heb4f9c7fb3ec450e9898ac806a576fb8f.webp?v=1779815527","url":"https:\/\/letsfibre.co.za\/products\/cisco-catalyst-3850-9300-power-supply-715w-ac-hot-swappable-plug-in-module-power-supply-module-with-24pin-715w-pwr-c1-715wac-p","provider":"Let's Fibre Technologies ","version":"1.0","type":"link"}